?:abstract
|
-
The objective of this study was to evaluate the validity and reliability of NG-Test® when used as a finger-prick test on healthcare workers and to compare it to the ELISA Wantai Immunoassay. Fifty-one healthcare workers who were RT-PCR SARS-CoV-2 positive and 59 who were RT-PCR SARS-CoV-2 negative accepted to participate in this study. They were subjected to an NG-Test® finger-prick test and collection of a blood sample on the same day. A second NG-Test® on another finger was performed for the first 30 cases and controls and read blinded to the first. Sera obtained from blood samples were used to perform the Wantai SARS-CoV-2 ELISA. The interobserver agreement for the NG-Test® test was perfect (kappa coefficient = 100% [98%–100%]). The sensitivity of NG-Test® was estimated to be 85% [71.9%–92.3%] and the specificity 98.3% [95.0%–100.0%]) for both IgG and IgM. The percentage of agreement between the Wantai immunoassay and NG-Test® was 92.73% for IgG (Kappa = 0.85 [0.75–0.95]) and 65.45% (Kappa = 0.42 [0.26–0.58]) for IgM. Our study highlights the need to validate rapid immunoassay tests under real-life conditions. If NG-Test® is used in seroprevalence surveys, we recommend that its diagnostic performance be taken into consideration to obtain a reliable estimation.
|
is
?:annotates
of
|
|
?:creator
|
|
?:doi
|
-
10.1080/22221751.2020.1852893
|
?:doi
|
|
?:journal
|
-
Emerging_microbes_&_infections
|
?:license
|
|
?:pdf_json_files
|
-
document_parses/pdf_json/3370a191932f592d72e0d954c43d5b0ca8885073.json
|
?:pmc_json_files
|
-
document_parses/pmc_json/PMC7717860.xml.json
|
?:pmcid
|
|
?:pmid
|
|
?:pmid
|
|
?:publication_isRelatedTo_Disease
|
|
?:sha_id
|
|
?:source
|
|
?:title
|
-
A lateral flow immunoassay test performance in SARS-CoV-2 seroprevalence surveys: a validation study among healthcare workers
|
?:type
|
|
?:year
|
|