PropertyValue
?:abstract
  • The synchrony of patient-ventilator interaction affects the process of mechanical ventilation which is clinically applied for respiratory support The occurrence of patient-ventilator asynchrony (PVA) not only increases the risk of ventilator complications but also affects the comfort of patients To solve the problem of uncertain patient-ventilator interaction in the mechanical ventilation system, a novel method to evaluate patient-ventilator synchrony is proposed in this article Firstly, a pneumatic model is established to simulate the mechanical ventilation system, which is verified to be accurate by the experiments Then, the PVA phenomena are classified and detected based on the analysis of the ventilator waveforms On this basis, a novel synchrony index SIhao is established to evaluate the patient-ventilator synchrony It not only solves the defects of previous evaluation indexes but also can be used as the response parameter in the future research of ventilator control algorithms The accurate evaluation of patient-ventilator synchrony can be applied to the adjustment of clinical strategies and the pathological analyses of patients This research can also reduce the burden on clinicians and help to realize the adaptive control of the mechanical ventilation and weaning process in the future
is ?:annotates of
?:creator
?:journal
  • Complexity
?:license
  • unk
?:publication_isRelatedTo_Disease
?:source
  • WHO
?:title
  • A Novel Method to Evaluate Patient-Ventilator Synchrony during Mechanical Ventilation
?:type
?:who_covidence_id
  • #825970
?:year
  • 2020