Property | Value |
?:abstract
|
-
Objective Severe cases of coronavirus disease 2019 (COVID-19) can require continuous renal replacement therapy (CRRT) and/or extracorporeal membrane oxygenation (ECMO). Unfractionated heparin (UFH) to prevent circuit clotting is mandatory but monitoring is complicated by (pseudo)-heparin resistance. In this observational study, we compared two different activated partial thromboplastin time (aPTT) assays and a chromogenic anti-Xa assay in COVID-19 patients on CRRT or ECMO in relation to their UFH dosages and acute phase reactants. Materials and Methods The aPTT (optical [aPTT-CS] and/or mechanical [aPTT-STA] clot detection methods were used), anti-Xa, factor VIII (FVIII), antithrombin III (ATIII), and fibrinogen were measured in 342 samples from 7 COVID-19 patients on CRRT or ECMO during their UFH treatment. Dosage of UFH was primarily based on the aPTT-CS with a heparin therapeutic range (HTR) of 50–80s. Associations between different variables were made using linear regression and Bland–Altman analysis. Results Dosage of UFH was above 35,000IU/24 hours in all patients. aPTT-CS and aPTT-STA were predominantly within the HTR. Anti-Xa was predominantly above the HTR (0.3–0.7 IU/mL) and ATIII concentration was >70% for all patients; mean FVIII and fibrinogen were 606% and 7.5 g/L, respectively. aPTT-CS correlated with aPTT-STA ( r (2) = 0.68) with a bias of 39.3%. Correlation between aPTT and anti-Xa was better for aPTT-CS (0.78 ≤ r (2) ≤ 0.94) than for aPTT-STA (0.34 ≤ r (2) ≤ 0.81). There was no general correlation between the aPTT-CS and ATIII, FVIII, fibrinogen, thrombocytes, C-reactive protein, or ferritin. Conclusion All included COVID-19 patients on CRRT or ECMO conformed to the definition of heparin resistance. A patient-specific association was found between aPTT and anti-Xa. This association could not be explained by FVIII or fibrinogen.
|
is
?:annotates
of
|
|
?:creator
|
|
?:doi
|
|
?:doi
|
|
?:journal
|
|
?:license
|
|
?:pdf_json_files
|
-
document_parses/pdf_json/ed722b590d984fc2fb1400390548d42d84767f14.json
|
?:pmc_json_files
|
-
document_parses/pmc_json/PMC7676995.xml.json
|
?:pmcid
|
|
?:pmid
|
|
?:pmid
|
|
?:publication_isRelatedTo_Disease
|
|
is
?:relation_isRelatedTo_publication
of
|
|
?:sha_id
|
|
?:source
|
|
?:title
|
-
Monitoring of Unfractionated Heparin in Severe COVID-19: An Observational Study of Patients on CRRT and ECMO
|
?:type
|
|
?:year
|
|