PropertyValue
?:abstract
  • SARS-CoV-2 is a recently emerged human coronavirus that has escalated to a pandemic. There are currently no approved vaccines for SARS-CoV-2, which causes severe respiratory illness or death. Defining the antibody response to SARS-CoV-2 will be essential for understanding disease progression, long-term immunity, and vaccine efficacy. Here we describe two methods for evaluating the neutralization capacity of SARS-CoV-2 antibodies. The basic protocol is a focus reduction neutralization test (FRNT), which involves immunostaining infected cells with a chromogen deposit readout. The alternate protocol is a modification of the FRNT that uses an infectious clone-derived SARS-CoV-2 virus expressing a fluorescent reporter. These protocols are adapted for use in a high-throughput setting, and are compatible with large-scale vaccine studies or clinical testing. © 2020 Wiley Periodicals LLC Basic Protocol: Focus reduction neutralization test Alternate Protocol: mNeonGreen-based focus reduction neutralization test (FRNT-mNG).
is ?:annotates of
?:creator
?:journal
  • Curr_Protoc_Immunol
?:license
  • unk
?:publication_isRelatedTo_Disease
is ?:relation_isRelatedTo_publication of
?:source
  • WHO
?:title
  • Development of a Rapid Focus Reduction Neutralization Test Assay for Measuring SARS-CoV-2 Neutralizing Antibodies
?:type
?:who_covidence_id
  • #935033
?:year
  • 2020