Property | Value |
?:abstract
|
-
SARS-CoV-2 is a recently emerged human coronavirus that has escalated to a pandemic. There are currently no approved vaccines for SARS-CoV-2, which causes severe respiratory illness or death. Defining the antibody response to SARS-CoV-2 will be essential for understanding disease progression, long-term immunity, and vaccine efficacy. Here we describe two methods for evaluating the neutralization capacity of SARS-CoV-2 antibodies. The basic protocol is a focus reduction neutralization test (FRNT), which involves immunostaining infected cells with a chromogen deposit readout. The alternate protocol is a modification of the FRNT that uses an infectious clone-derived SARS-CoV-2 virus expressing a fluorescent reporter. These protocols are adapted for use in a high-throughput setting, and are compatible with large-scale vaccine studies or clinical testing. © 2020 Wiley Periodicals LLC Basic Protocol: Focus reduction neutralization test Alternate Protocol: mNeonGreen-based focus reduction neutralization test (FRNT-mNG).
|
is
?:annotates
of
|
|
?:creator
|
|
?:journal
|
|
?:license
|
|
?:publication_isRelatedTo_Disease
|
|
is
?:relation_isRelatedTo_publication
of
|
|
?:source
|
|
?:title
|
-
Development of a Rapid Focus Reduction Neutralization Test Assay for Measuring SARS-CoV-2 Neutralizing Antibodies
|
?:type
|
|
?:who_covidence_id
|
|
?:year
|
|