Property | Value |
?:abstract
|
-
A robust supercritical chromatography (SFC) method using an Enantiocel C2-5 column was developed for the multigram separation of the enantiomers of hydroxychloroquine (HCQ), affirming its use as a scalable technology and ability to provide quantities of each enantiomer for clinical evaluation. The enantiomers of HCQ were collected on a gram scale with greater than 99% enantiomeric excess. The S and R enantiomer elution order was confirmed using optical rotation determinations with comparison to previously determined assignments.
|
is
?:annotates
of
|
|
?:creator
|
|
?:journal
|
|
?:license
|
|
?:publication_isRelatedTo_Disease
|
|
?:source
|
|
?:title
|
-
A preparative chiral separation of hydroxychloroquine using supercritical fluid chromatography
|
?:type
|
|
?:who_covidence_id
|
|
?:year
|
|